Digitized maps available for 14 of 14 catalog models.
Nearby sizes
Exhaust housing on the map
With the 1.01 A/R T4 housing, boost reaches 13 psi at about 5,250 rpm, later than your 4,000 rpm target. At 7,000 rpm, the housing model estimates 499 crank hp, about 1 hp below your 500 crank hp goal. The curve below 5,250 rpm follows your target’s shape; it does not predict spool.
1.01 A/R T4: 13 psi from ≈5,250 rpm · ≈499 crank hp
Hover the map to read any point. Drag the large dot to change your power goal.
Map screen: Garrett G45-1610 with the 1.01 A/R T4 housing Tight margin
Estimated operating points stay within the traced compressor map.
- 70% efficient at your 7,000 rpm power peak
- 1% of the map’s width clear of surge from full boost at 5,250 rpm
- Peak-only map screen: up to about 1,265 crank hp on this engine, before housing effects
- Housing model: 499 crank hp at peak vs 500 crank hp goal (1 hp short).
Map screen only; does not predict spool or confirm a complete, safe setup.
Garrett G45-1610 with 1.01 A/R T4 Tight margin
Housing model: 499 crank hp at peak vs 500 crank hp goal (1 hp short).
Map screen details
With the 1.01 A/R T4 housing, boost reaches 13 psi at about 5,250 rpm, later than your 4,000 rpm target. At 7,000 rpm, the housing model estimates 499 crank hp, about 1 hp below your 500 crank hp goal. The curve below 5,250 rpm follows your target’s shape; it does not predict spool.
Map screen: Garrett G45-1610 with the 1.01 A/R T4 housing Tight margin
Estimated operating points stay within the traced compressor map.
- 70% efficient at your 7,000 rpm power peak
- 1% of the map’s width clear of surge from full boost at 5,250 rpm
- Peak-only map screen: up to about 1,265 crank hp on this engine, before housing effects
- Housing model: 499 crank hp at peak vs 500 crank hp goal (1 hp short).
Map screen only; does not predict spool or confirm a complete, safe setup.
Show values by rpm
| rpm | 2k | 2.5k | 3k | 3.5k | 4k | 4.5k | 5k | 5.5k | 6k | 6.5k | 7k |
|---|---|---|---|---|---|---|---|---|---|---|---|
| hp | 73 | 100 | 156 | 230 | 292 | 330 | 367 | 403 | 438 | 470 | 500 |
| psi | 0.0 | 1.0 | 5.3 | 10.4 | 12.8 | 12.8 | 12.8 | 12.8 | 12.8 | 12.8 | 12.8 |
| eff | spool | spool | spool | spool | surge | surge | surge | under 68% | under 68% | 69% | 70% |
| hp 1.01 A/R T4 | 72 | 91 | 112 | 152 | 217 | 294 | 363 | 404 | 438 | 469 | 499 |
| psi 1.01 A/R T4 | 0.0 | 0.0 | 0.1 | 2.1 | 5.9 | 9.8 | 12.4 | 12.8 | 12.8 | 12.8 | 12.8 |
Exhaust housings for the G45-1610
Smaller A/Rs tend to reach boost earlier but add backpressure at peak power. These estimates use Garrett turbine curves and a steady-state model at 12.8 psi.
Show estimates for each housing
| Housing | Holds 13 psi from | Crank hp at 7,000 rpm | Backpressure at 7,000 rpm | Drive ratio | Wastegate bypass |
|---|---|---|---|---|---|
| 1.01 A/RT4 inlet · Divided · External wastegate | 5,250 rpm | ~499 | ~14 psi | ~1.03:1 | ~17% |
| 1.01 A/RV-Band inlet · External wastegateCurve estimated from Garrett’s 1.01 A/R T4 curve | 5,250 rpm | ~499 | ~14 psi | ~1.03:1 | ~17% |
| 1.15 A/RT4 inlet · Divided · External wastegate | 5,500 rpm | ~500 | ~13 psi | ~1.00:1 | ~13% |
| 1.15 A/RV-Band inlet · External wastegateCurve estimated from Garrett’s 1.15 A/R T4 curve | 5,500 rpm | ~500 | ~13 psi | ~1.00:1 | ~13% |
| 1.28 A/RT4 inlet · Divided · External wastegate | 5,750 rpm | ~501 | ~12 psi | ~0.98:1 | ~10% |
| 1.28 A/RV-Band inlet · External wastegateCurve estimated from Garrett’s 1.28 A/R T4 curve | 5,750 rpm | ~501 | ~12 psi | ~0.98:1 | ~10% |
| 1.44 A/RT4 inlet · Divided · External wastegate | 6,250 rpm | ~501 | ~12 psi | ~0.97:1 | ~8% |
| 1.44 A/RV-Band inlet · External wastegateCurve estimated from Garrett’s 1.44 A/R T4 curve | 6,250 rpm | ~501 | ~12 psi | ~0.97:1 | ~8% |
Steady-state estimate: 1,600°F turbine inlet, 72% turbine efficiency (our default; Garrett doesn’t publish a peak for this turbine), 1.5 psi downpipe loss, 9.5:1 compression. Power counts only the exhaust left in the cylinder, not valve overlap, so the top-end loss from a small housing is likely understated. Garrett doesn’t publish the turbine map’s reference conditions. Against Garrett’s G35-1050 2JZ test this method reads about 10% under the measured backpressure. Real response also depends on transient spool, the manifold and the tune. Adjust these under calculation assumptions.
Digitized maps available for 14 of 14 catalog models.